From sound isolation and absorption to diffusion and floating structures, we use acoustic calculations to deliver complete solutions for recording studios, film mixing stages and professional listening spaces.
Acoustic Construction adapts existing spaces for acoustic performance through structural work, floating structures, sound isolation, absorption, reflection and diffusion, alongside air conditioning, ventilation, power and signal systems. These elements are combined to achieve appropriate reverberation time, sound insulation and background noise levels, controlling coloration, standing waves, flutter echo and feedback to create clear, balanced and full sound that meets professional requirements.
An existing empty room is acoustically renovated for ADR dialogue recording, DI color grading, post-production mixing and video editing, with separate recording and control rooms.
Acoustic design starts with the purpose of each space and follows national standards, acoustic calculations and performance targets to control reverberation and eliminate sound defects for film production. Interior materials meet fire rating B1 or higher and environmental grade E1. High-density isolation materials support NR25 background noise and 55dB wall isolation, with walls 15–30cm thick. Ceiling resonators address coloration and coincident modes across frequency bands.
| Frequency Band | Target T60 |
|---|---|
| Low · 63–250Hz | 0.3 – 0.5 s |
| Mid · 500Hz–2kHz | 0.4 – 0.6 s |
| High · 4kHz–8kHz+ | 0.35 – 0.5 s |
Ceiling absorption is central to room acoustics. A composite sound-isolating and absorptive ceiling works with resonators tuned to different frequency bands.
Highly absorptive, sound-isolating walls achieve 55dB isolation, with materials selected for appearance and fire safety.
Professional sound-isolating doors and sound locks provide overall isolation of 55dB.
Studio dry floating floor: 35mm / 80kg·m⁻³ vibration isolation layer with timber framing + one 18mm blockboard layer + two 12mm gypsum board layers + carpet finish
Reverberation time is designed by frequency band (0.3–0.6s overall). Sound focusing, echoes and flutter echoes are largely eliminated. Project targets reference Dolby Laboratories mixing studio design standards.
Rough construction proceeds from the bottom up, while finishes proceed from the top down. Audio and video systems follow conduits and cables → equipment installation → calibration. Interior elevations use the floor +50cm reference line. Electrical distribution and lighting are coordinated with ventilation, air conditioning, noise reduction and sound isolation.
* The above standards are construction references
Material layers and specifications follow acoustic calculations, with fire safety and environmental requirements checked individually.
| Building Element | Material Layers and Specifications |
|---|---|
| Sound-Isolating Ceiling | Suspension hangers + series 50 light steel framing + 50mm / 32kg·m⁻³ absorption layer + vibration isolation pads + two layers of 12mm gypsum board |
| Absorptive Ceiling | Timber framing + 50mm / 32kg·m⁻³ absorption layer + polyester acoustic panels or suede fabric finish |
| Perimeter Lightweight Sound-Isolating Walls | Series 75 light steel framing + vibration isolation pads + 50mm / 32kg·m⁻³ absorption layer + 2×12mm gypsum board + acoustic sealant and joint compound |
| Double-Layer Studio Sound-Isolating Walls | Repeat the lightweight sound-isolating wall assembly to further improve sound isolation. |
| Absorptive Walls | Blockboard framing (two 18mm layers, 100mm wide) + 25mm / 32kg·m⁻³ absorption layer + 9mm polyester fiber or suede fabric finish |
| Floating Floor | Studio dry floating floor: 35mm / 80kg·m⁻³ vibration isolation layer with timber framing + one 18mm blockboard layer + two 12mm gypsum board layers + carpet finish |
| Sound-Isolating Doors | Custom steel acoustic doors rated at 30dB, combined with sound locks for overall 55dB isolation |
| Power Conduits and Wiring | Galvanized JDG conduits, ∮20 / ∮25, 1.2mm wall thickness; flame-retardant copper wiring ZR-BV2.5 / ZR-BV4.0 |
| Lighting System | 15W downlights for general lighting, combined with ambient and decorative wall lighting |